產(chǎn)品中心
PRODUCTS CENTER
所屬分類:
美國泰克
矢量網(wǎng)絡(luò)分析儀
產(chǎn)品詳細
Legendary support and quality meets ease-of-use and affordability. The Tektronix TTR500 series 2-port, 2-path VNA is our latest breakthrough - an unmatched combination of measurement performance and convenience. Get the power to make everyday measurements with the accuracy and confidence you expect from Tektronix, all without breaking your budget.
Key performance specifications
- 100 kHz to 6 GHz frequency range
- > 122 dB dynamic range
- -50 to +7 dBm output power
- < 0.008 dB RMS trace noise
Key features
- Full 2-port 2-path S-parameter measurement (S11, S21, S12, S22) in a variety of formats.
- Complete vector network analysis capability with Tektronix VectorVu-PC™ software.
- Built-in bias tee accessible on both ports to bias active devices.
- Application programming interface (API) for Microsoft Windows environment and LabView driver.
- Robust SCPI command interface (compatible with current VNA models) to optimize code migration.
- Touchstone file support (import/export) for use with Electronic Design Automation (EDA) simulation tools.
- Offline simulation mode for analysis of S-parameter files when disconnected from the instrument.
- Industry-leading three year warranty.
Applications
- Antenna matching and tuning
- RF component design and validation
- Education
Specifications
All specifications are warranted performance characteristics with guaranteed tolerance limits, unless noted otherwise. All specifications are valid between 18 °C and 28 °C ambient temperature and apply to all models unless noted otherwise.
Nominal refers to the features or characteristics of the design.
Typical indicates that 80% of units will meet the published typical performance with 80% confidence, unless otherwise noted. Typical performance is not warranted.
Typical-Mean indicates the mean performance measured on a sample of units immediately after performing an alignment. Typical-Mean performance is not warranted.
General
- Connectivity
- USB 2.0
- Software
- VectorVu-PC™ (requires Windows® 7/8/10, 64-bit)
Corrected system performance with calibration kit
- Spinner Type-N mechanical calibration kit BN533861
-
User Correction ON.
Two 60 cm Tektronix cables 012-1765-00 or 012-1768-00
Frequency Directivity
(dB)
Source match
(dB)
Load match:
Insertable devices (dB)
Load match with M-M or F-F thru
(dB)
Reflection tracking
(dB)
Transmission tracking:
Insertable devices (dB)
300 kHz to < 1 MHz -38 -34 -37 -35 0.08 0.05 1 MHz to < 10 MHz -37 -34 -37 -35 0.08 0.02 10 MHz to < 100 MHz -37 -34 -37 -35 0.08 0.01 100 MHz to < 1 GHz -36 -34 -37 -35 0.08 0.01 1 GHz to < 3 GHz -36 -34 -37 -35 0.08 0.02 3 GHz to 6 GHz -36 -34 -36 -35 0.09 0.02 18 °C to 28 °C, within 1 °C of calibration temperature and at the same ambient humidity conditions in which calibration was performed. - Spinner 3.5 mm mechanical calibration kit BN533854
-
User Correction ON.
Two 60 cm Tektronix cables 012-1769-00 or 012-1772-00
Frequency Directivity
(dB)
Source match
(dB)
Load match:
Insertable devices (dB)
Load match with M-M or F-F thru
(dB)
Reflection tracking
(dB)
Transmission tracking:
Insertable devices (dB)
300 kHz to < 1 MHz -36 -33 -37 -35.5 0.1 0.06 1 MHz to < 10 MHz -35 -33 -37 -35.5 0.1 0.02 10 MHz to < 100 MHz -35 -33 -37 -35.5 0.1 0.01 100 MHz to < 1 GHz -35 -33 -35 -35.5 0.1 0.01 1 GHz to < 4 GHz -35 -33 -35 -35.5 0.1 0.02 4 GHz to 6 GHz -28 -28 -29 -29 0.22 0.03 18 °C to 28 °C, within 1 °C of calibration temperature and at the same ambient humidity conditions in which calibration was performed. - Spinner Type-N calibration kit BN533844
-
User Correction ON.
Two 60 cm Tektronix cables 012-1765-00
Frequency Directivity
(dB)
Source match
(dB)
Load match:
Insertable devices (dB)
Load match with M-M or F-F thru
(dB)
Reflection tracking
(dB)
Transmission tracking:
(dB)
300 kHz to < 1 MHz -32 -31 -32 -31 0.15 0.07 1 MHz to < 10 MHz -32 -31 -32 -31 0.15 0.03 10 MHz to < 100 MHz -31 -31 -32 -31 0.15 0.01 100 MHz to < 1 GHz -31 -31 -32 -31 0.15 0.01 1 GHz to < 4 GHz -31 -31 -32 -31 0.15 0.02 4 GHz to 6 GHz -25 -25 -26 -26 0.3 0.04 18 °C to 28 °C, within 1 °C of calibration temperature and at the same ambient humidity conditions in which calibration was performed.
Uncorrected system performance
- User correction OFF. Factory correction ON.
Frequency Directivity
(dB)
Source match
(dB)
Load match
(dB)
Reflection tracking
(dB)
Transmission tracking
(dB)
300 kHz to < 500 kHz -25 -25 -4.5 ±1 ±1 500 kHz to < 2 MHz -25 -25 -4.5 ±1 ±1 2 MHz to < 10 MHz -25 -25 -11 ±1 ±1 10 MHz to < 200 MHz -25 -25 -11 ±1 ±1 200 MHz to <1.5 GHz -25 -25 -10 ±1 ±1 1.5 GHz to < 4.5 GHz -25 -25 -8 ±1 ±1 4.5 GHz to < 5 GHz -25 -25 -7 ±1 ±1 5 GHz to 6 GHz -25 -25 -7 ±1 ±1
Frequency
- TTR503A
- 100 kHz to 3.0 GHz
- TTR506A
- 100 kHz to 6.0 GHz
- Range
- Resolution
- 1 Hz
- Accuracy
- ± 7.0 ppm over 1 year calibration interval, 18 °C to 28 °C
- Frequency
- 10 MHz
- Initial accuracy
- ±10 Hz
Aging
- Internal reference
- ± 0.9 ppm/year
- External reference input
- 10 MHz ± 50 Hz
Test port output
- Dynamic range
-
Description 300 kHz to < 1 MHz
1 MHz to < 2 MHz
2 MHz to < 200 MHz
200 MHz to < 3 GHz
3 GHz to
< 4.5 GHz
(TTR506A only)
4.5 GHz to 6 GHz
(TTR506A only)
Dynamic range Typical 112 dB 117 dB 124 dB 125 dB 123 dB 122 dB Specification - - - 124 dB 123 dB 122 dB Noise floor -110 dBm/Hz
(< -115 dBm/Hz typical)< -120 dBm/Hz
(< -125 dBm/Hz typical)< -120 dBm/Hz
(< -125 dBm/Hz typical)< -125 dBm/Hz
(< -130 dBm/Hz typical)< -125 dBm/Hz
(< -130 dBm/Hz typical)< -125 dBm/Hz
(< -130 dBm/Hz typical)
- Crosstalk with load
-
Description 300 kHz to
< 1 MHz
1 MHz to
< 10 MHz
10 MHz to
< 200 MHz
200 MHz to
< 1 GHz
1 GHz to
< 2 GHz
2 GHz to 6 GHz
(TTR506A only above 3 GHz)
Uncorrected crosstalk with load -85 dB -110 dB -105 dB -120 dB -115 dB -120 dB Corrected crosstalk with load 1 - 90 dB -118 dB -115 dB -125 dB -125 dB -120 dB
1After full 2-port SOLT calibration with isolation using a Spinner BN533861 Type-N 50 Ω load.
Dynamic accuracy and compression
- Dynamic accuracy
-
Received level range 105 MHz 2 GHz > +5 to +10 dBm 0.65 dB 0.4 dB > 0 to +5 dBm 0.35 dB 0.2 dB > -20 to 0 dBm 0.2 dB 0.15 dB > -34 to -20 dBm 0.25 dB 0.2 dB > -50 to -34 dBm 0.35 dB 0.3 dB > -60 to -50 dBm 0.55 dB 0.45 dB - Dynamic accuracy, typical-mean
-
Received level range 10 MHz 105 MHz 350 MHz 783.5
MHz
1.083
GHz
2 GHz 3 GHz 4 GHz 5.25 GHz 6 GHz > +5 to +10 dBm 0.4 dB 0.3 dB 0.3 dB 0.3 dB 0.25 dB 0.2 dB 0.2 dB 0.15 dB 0.15 dB 0.15 dB > 0 to +5 dBm 0.25 dB 0.25 dB 0.1 dB 0.1 dB 0.1 dB 0.05 dB 0.05 dB 0.05 dB 0.05 dB 0.05 dB > -30 to 0 dBm 0.15 dB 0.1 dB 0.1 dB 0.1 dB 0.1 dB 0.1 dB 0.1 dB 0.1 dB 0.1 dB 0.1 dB -50 to -30 dBm 0.2 dB 0.15 dB 0.15 dB 0.15 dB 0.15 dB 0.15 dB 0.15 dB 0.15 dB 0.15 dB 0.15 dB
- Test port compression at maximum input level
- Compression at +10 dBm input level (typical-mean) is > +5 to +10 dBm
Frequency 10 MHz 105 MHz 350 MHz 783.5
MHz
1.083
MHz
2 GHz 3 GHz 4 GHz 5.25 GHz 6 GHz Compression 0.4 dB 0.4 dB 0.3 dB 0.25 dB 0.25 dB 0.2 dB 0.2 dB 0.2 dB 0.2 dB 0.2 dB
- Trace noise 1, typical
-
300 KHz to < 200 MHz 200 MHz to 6 GHz Magnitude 0.008 dB RMS 0.006 dB RMS Phase 0.05 degrees RMS 0.04 degrees RMS
1Measured in a 1 KHz IF BW, 10 dBm output power, thru connection
- Temperature stability 1, typical
-
300 KHz to 3 GHz > 3 GHz to 6 GHz Magnitude 0.008 dB/°C 0.015 dB/°C Phase 0.1 degrees/°C 0.2 degrees/°C
1Measured in a 10 Hz IF BW, 0 dBm output power, thru connection
-
DC < 10 MHz ≥ 10 MHz to 6 GHz Operational ± 24 V 10 dBm 10 dBm Without damage ± 30 V 15 dBm 20 dBm
- Maximum receiver input level
Output level calibration
-
Manufacturer Supported power sensors Tektronix USB power sensors PSM3000 series
PSM4000 series
PSM5000 seriesKeysight USB power sensors U848x series
U2020 series
U2000 seriesRohde and Schwarz USB power sensors NRP-Z power sensors
NRP-xxS/SN power sensors
Connectors
-
Name Function Description Port 1 VNA measurement port 1 Type N female conductor Port 2 VNA measurement port 2 Type N female conductor LO A LO A In/Out SMA female conductor LO B LO B In/Out SMA female conductor Power Power indicator Red/green LED
- Front panel
-
-
Name Function Specifications Connector Bias 1 Port 1 bias tee connection ± 24 VDC
± 200 mA maximumBNC Female Bias 2 Port 2 bias tee connection Ref Out 10 MHz reference output 10 MHz ± 60 Hz
> 5 dBmRef In 10 MHz reference input 10 MHz ± 50 Hz
-5 dBm to + 10 dBmTrigger Trigger input TTL
± Edge, ± Level
> 250 μS duration (10 mS max.)Aux Sync Auxiliary trigger TTL DC input Power supply 4.752 to 5.25 VDC 2.5 x 5.5 x 9.5 mm barrel connector
Center positiveUSB 2.0 USB connector for computer connection USB 2.0 USB 2.0 B connector
- Rear panel
-
Power supply
-
Tektronix part number Input Output 119-8763-01 100 to 240 V AC, 50/60 Hz
IEC60320 C14 receptacle+ 5 V ±1%
4 A maximum
VectorVu-PC™ software
- System requirements
-
Processor Memory Drive Best Intel® Core™ i7 8 GB SSD Recommended Intel® Core™ i3 8 GB SSD Minimum Intel® Core™ i3 8 GB HDD Operating system: Windows® 7 or greater, 64-bit
Physical characteristics
-
Length: 11.25” (28.58 cm)
Width: 8.125” (20.64 cm)
Depth: 1.75” (4.45 cm)
Weight: 3.5 lbs. (1.59 kg)
Environmental and safety
- Temperature
-
Operating: +5 °C to +50 °C ( 41 °F to 122 °F)
Non-operating: -40 °C to 71 °C ( -40 °F to 159.8 °F)
- Humidity (operating)
-
5% to 80% ±5%RH (relative humidity) in the temperature range of +10 °C to 30 °C (+50 °F to 86 °F)
5% to 75% ±5%RH above +30 °C to 40 °C (+86 °F to 104 °F)
5% to 45% ±5%RH above +40 °C up to 50 °C (+104 °F to +122 °F)
Non-condensing
- Altitude
-
Operating: 5000 m (16,404 ft)
Non-operating: 15,240 m (50,000 ft)
- Vibration
-
Operating: 0.31 GRMS: 5-500 Hz, 3 Axes at 10 min/axis
Non-operating: 2.46 GRMS: 5-500 Hz, 3 Axes at 10 min/axis
- Shock
-
Operating: Half-sine mechanical shocks, 30 g peak amplitude, 11 msec duration, 3 drops in each direction of each axis, 18 total
Non-operating: Half-sine mechanical shocks, 40 g peak amplitude, 11 msec duration, 3 drops in each direction of each axis, 18 total
- Dynamics
- Handling and transit
-
Bench handling, operating: MIL-PRF-28800F Class 3
Transit drop, non-operating: MIL-PRF-28800F Class 2
相關(guān)下載
2021-04-16