產(chǎn)品中心
PRODUCTS CENTER
所屬分類:
美國(guó)泰克
功率分析儀
產(chǎn)品詳細(xì)
The Tektronix PA3000 is a one to four channel power analyzer that is optimized for testing today’s single and multi-phase, high efficiency power conversion products and designs. Use it to quickly visualize, analyze, and document power efficiency, energy consumption, and electrical performance to the latest regional and international standards, including Level VI, EnergyStar, CEC, IEC 62301, CQC-3146, and more.
Key features and specifications
- One to four channels support single and three phase applications
- 10 mW standby power measurement
- 1 MHz bandwidth
- 1 MS/s sampling rate
- 16 bit A/D
- Harmonic analysis to 100th order
- ±0.04% basic voltage and current accuracy
- Measurements to 30 Arms and 600 Vrms Cat II (2000 Vpk)
- USB and LAN interfaces standard (GPIB option)
- Free PWRVIEW software
- Full color graphical display for intuitive readouts of measured values, waveforms, harmonics, and energy integration plots
The essential power measurement tool for R&D and validation
- High accuracy supports testing to Level VI efficiency standards for external AC/DC power supplies
- Dedicated energy consumption testing in integration mode for standards like Energy star and CEC
- Complete solution for full compliance testing to IEC 62301 standby power requirements
- High 1 MHz bandwidth supports the LED module energy certification requirements of CQC-3146 as well as harmonic analysis of designs with higher fundamental frequencies
- More than 50 standard measurement functions, including harmonics, frequency, and star-delta computation
- Multiple analog and digital inputs for sensor data such as thermocouples, speeds sensors, and torques sensors
- Built-in ±15 V supplies for external transducers to support high current applications
Applications
- AC/DC power supplies and LED drivers
- Appliances and consumer electronics
- UPS systems, inverters, and DC/AC conversion systems
- Wireless battery charging
- Three phase motors and drives
Specifications
All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise. Specifications are subject to change without notice.
For detailed information on the PA3000 Power Analyzer product specifications refer to the Model PA3000 Power Analyzer Instrument Specifications document, Tektronix part number 077-1252-00 downloadable fromwww.tek.com/manual/downloads.
Current accuracy
- 1 A shunt
- ±0.04% reading ±0.04% range
- 30 A shunt
- ±0.04% reading ±0.04% range
- External shunt
- ±0.1% reading ±0.04% range
- Accuracy Arms
- (45 Hz to 850 Hz)
- 1 A shunt
- ±(0.05 + 2×10-5 × f)% reading ±0.05% range ±40 μA
- 30 A shunt
- ±(0.05 + 2×10-5 × f)% reading ±0.05% range ±4 mA
- External shunt
- ±(0.1 + 2×10-5 × f)% reading ±0.05% range ±1.1 mV
- Accuracy Arms, typical
- (10 Hz to 45 Hz, 850 Hz to 1 MHz)
- 1 A shunt
- ±0.05% reading ±0.1% range ±100 μA
- 30 A shunt
- ±0.05% reading ±0.1% range ± 10mA
- External A shunt
- ±0.1% reading ±0.1% range ±1.1 mV
- Accuracy Adc
- 1 A shunt
- 12.5 mA, 25 mA, 50 mA, 125 mA, 250 mA, 500 mA, 1.25 A, 2.5 A, 5 A
- 30 A shunt
- 500 mA, 1 A, 2 A, 5 A, 10 A, 20 A, 50 A, 100 A, 200 A
- External A shunt
- 50 mV, 100 mV, 200 mV, 500 mV, 1 V, 2 V, 5 V, 10 V, 20 V
- Ranges
- (peak)
Voltage accuracy
- Accuracy Vrms (45 Hz to 850 Hz)
- ±0.04% reading ±0.04% range
- Accuracy Vrms (10 Hz to 45 Hz, 850 Hz to 1 MHz), typical
- ±(0.05 + 1×10-5 × f)% reading ±0.05% range ±20 mV
- Accuracy Vdc
- ±0.05% reading ±0.1% Range ±50 mV
- Ranges (peak)
- 5 V, 10 V, 20 V, 50 V, 100 V, 200 V, 500 V, 1000 V, 2000 V
Supplemental characteristics
The following specifications are supplemental characteristics that provide additional information about instrument functions and performance. These characteristics are non-warranted specifications; they describe the typical performance of the PA3000.
For detailed information on the PA3000 Power Analyzer product specifications refer to the Model PA3000 Power Analyzer Instrument Specifications document, Tektronix part number 077-1252-00 downloadable fromwww.tek.com/manual/downloads.
- Hours accuracy
- ±0.0125%
- Watts accuracy (45 Hz to 850 Hz)
- ±(Vrmsacc × Arms) ±(Armsacc × Vrms)
- Watt hour accuracy
- ±(Wattacc + Houracc)
- VA accuracy (45 Hz to 850 Hz)
- ±(Vrmsacc × Arms) ±(Armsacc × Vrms)
- PF accuracy
- Wacc / VA
- 0.1 Hz to 10 Hz
- 0.1% of reading
- 10 Hz to 1 MHz
- 0.5% of reading
- Frequency accuracy
- Ranges
- 10 Vdc range: ±1 V to ±10 V
Vdcrange: ±0.1 V to ±1 V
- Accuracy
- ±0.2% of reading ±0.2% of range ±0.005 V
- Sample rate
- 1000 samples per second
- Analog inputs
Communications
- IEEE-488 (Option)
- IEEE Std 488.1 compliant
- RS-232
-
Baud rates from 9600 bps, 19200 bps (default), and 38400 bps
8 bit, No parity, 1 stop bit, hardware flow control
9 pin male D-type connector
- Ethernet
-
IEEE 802.3 compatible, 10Base-T
RJ-45 connector with Link and Activity indicators
TCP/IP connection on port 5025
- USB device
- USB 2.0 compatible, Full speed (12 Mb/sec)
General specifications
- EMC
- Conforms to European Union EMC directive
- Safety
- Conforms to European Union Low Voltage directive
- Operating
- 0 °C to 40 °C (32 °F to 104 °F), 70% relative humidity up to 31 °C (87.8 °F)
- Storage
- -25 °C to 65 °C (-13 °F to 149 °F)
- Temperature
- Altitude
- Up to 2000 m (6562 ft) above sea level
- Warm up time
- One hour
- Calibration period
- One year
- Power supply
- 100 V to 240 VAC, 50 Hz or 60 Hz, 120 VA maximum
- Transducer power supply
- ±15 V, Maximum current 250 mA per analog card
- Dielectric strength
-
Mains supply inlet (Live + Neutral to earth): 1.5 kVAC
Voltage measurement inputs : 2 kVpkto earth
Current measurement inputs : 2 kVpkto earth
- With handle and feet
-
14.6 cm high × 45 cm wide × 33.5 cm deep (5.75 in × 17.75 in × 13.2 in)
- Without handle and feet
-
13.2 cm high × 42 cm wide × 33.5 cm deep (5.2 in × 16.5 in × 13.2 in)
- Dimensions
- Weight
- 9.5 kg (20.9 lb) – 4 channel instrument with GPIB option installed
- Warranty
- Three years
相關(guān)下載
2021-04-16